AKH-0.66 Series II Type Current Transformer for Measurement
AKH-0.66 series current transformer, its shell is formed by press mould with high temperature resistant material.THe core ,The Second wires adopt high strength electromaagetic wire .This product have features of novel construction,goood appearance,mounting ease,samller volume ,higher accuracy ,higher capacity.This product meet the requirements of GB 20840.2-2014(IEC61869-2:2012,MOD), and have achieved CE certificate.
*l Measuring CT primary current 5-6300A,secondary current 5A,1A,100mA,50mA;
Integrated CT primary current 5-200A,secondary current 5A,1A,20mA,50mA;
Micro CT primary current 5-100A,secondary current 20mA,50mA;
Protection CT primary current 5-6300A,secondary current 5A,1A,100mA,50mA;
Double-winding CT primary current 5-6300A,second current 5A,20mA,1A,20mA;
Double-winding sensor primary current 5-6300A,secondary current AC5A,DC4-20mA,AC 1A,DC4-20mA;
Residual current CT primary current 0-5A,secondary output voltage 1V or current 5mA or current 2mA;
Metering CT primary current 5-5000A,secondary current 5A,1A;
Split CT primary current 20-6300A,secondary current 5A,1A;
Casting CT primary current 75-20000A,secondary current 5A,1A.
*Rated operation voltage AC 0.66kV(Equivalent AC 0.69kV,GB156-2003)
*Rated frequency 50-60Hz
*Ambient air temperature -30ºC-70ºC
* Height above sea level≤3000m
*Power frequency withstand voltage 3000v/1min 50Hz
*Used in place without direct rain and snow,without severe pollution and acute shock
* Other special requirements can be customized

*l Measuring CT primary current 5-6300A,secondary current 5A,1A,100mA,50mA;
Integrated CT primary current 5-200A,secondary current 5A,1A,20mA,50mA;
Micro CT primary current 5-100A,secondary current 20mA,50mA;
Protection CT primary current 5-6300A,secondary current 5A,1A,100mA,50mA;
Double-winding CT primary current 5-6300A,second current 5A,20mA,1A,20mA;
Double-winding sensor primary current 5-6300A,secondary current AC5A,DC4-20mA,AC 1A,DC4-20mA;
Residual current CT primary current 0-5A,secondary output voltage 1V or current 5mA or current 2mA;
Metering CT primary current 5-5000A,secondary current 5A,1A;
Split CT primary current 20-6300A,secondary current 5A,1A;
Casting CT primary current 75-20000A,secondary current 5A,1A.
*Rated operation voltage AC 0.66kV(Equivalent AC 0.69kV,GB156-2003)
*Rated frequency 50-60Hz
*Ambient air temperature -30ºC-70ºC
* Height above sea level≤3000m
*Power frequency withstand voltage 3000v/1min 50Hz
*Used in place without direct rain and snow,without severe pollution and acute shock
* Other special requirements can be customized

Type | Ratio(A) | Degree of Accuracy&Rated load(VA) | Turns | Bus spec.(mm)/number | ||
0.2 | 0.5 | 1 | ||||
200*50II 220*50II 260*50II | 1500-2000/5(1) | 20 | 1 | 200*10/1-3 100*10/4-6 | ||
2500-5000/5(1) | 30 | 1 |